19 9223-OM (V2.0)
recommend that this be addressed. If Alarm on Link Loss is set to Yes, the
Dashboard Card State will be yellow if there are no higher-priority alarms
present.
o No Link: The port does not currently have link. If Alarm on Link Loss is set to
Yes, the Dashboard Card State will be red and the Status LED in the front of the
board will also be red. If Alarm on Link Loss is set to No, this indicator will still be
red, but the alarm will not propagate.
Port 1/2 Status: This indicator is the port overrun status. It has the following states:
o OK: The port is operating normally.
o TX Overflow: In the current configuration, the IP outputs are attempting to
transmit more than the port capacity (i.e., the overall output data for this port
exceeds the interface speed of 100 Mb/s or 1 Gb/s). The Dashboard Card State
will be red and the Status LED in the front of the board will also be red. In this
case, reduce the output bit rate (either by reducing the encoder bit rates or by
removing output ports). If this indicator is red, data is being dropped.
Link Speed (Mb/s): This parameter reports the actual speed negotiated with the switch
for the port. If the port has no link, the value reported here is zero.
MAC Address: This reports the MAC address of the Ethernet port.
Network Statistics DNS Tab
The Network Statistics DNS Tab reports the current DNS configuration.
Encoder 1, Encoder 2 Tabs
The Encoder 1/Encoder 2 Tabs are used to configure/monitor the individual encoder channels.
The parameters in these two tabs are identical.
Encoder Configuration Tab
The Encoder Configuration Tab is further divided into the following 3 tabs:
Basic Tab: contains the more important configuration parameters, which all users are
likely to change.
Advanced Tab: contains the advanced configuration parameters, which do not
necessarily need to be changed.
Connections Tab: allows the creation of connections between this encoder and the ASI
and IP output ports.